Dascom TallyCom III Installation & Operators Guide Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Drucker Dascom TallyCom III Installation & Operators Guide herunter. Dascom TallyCom III Installation & Operators Guide User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
TallyCom III Twinax/Coax/Ethernet IIF-4
Printserver for Matrix Printers
Installation & Operator’s Guide
D10587-01
October 2009
DASCOM Europe GmbH
Heuweg 3
D-89079 Ulm
Germany
www.dascom.com
support.gb@dascom.com
Seitenansicht 0
1 2 3 4 5 6 ... 59 60

Inhaltsverzeichnis

Seite 1

TallyCom III Twinax/Coax/Ethernet IIF-4 Printserver for Matrix Printers Installation & Operator’s Guide D10587-01 October

Seite 2 - Table of contents

4 Programming the Printserver The Printserver supports a number of internal setup functions, known as FSL (Function Selection via the Line). This cha

Seite 3 - 1 Introduction

The cost of having an escape character defined is that you will not be able to print this character. However, you do not need to have an escape chara

Seite 4

4.5 Sending Hex Codes After you have defined an escape character you may send any printer command string using HEX codes to the Printserver. Here is

Seite 5 - 1.4.1 Related Manuals

TEST NO. TEST 1 OFFLINE HEX Dump of IBM Buffer ( Coax Only ) 2 ONLINE HEX Dump of IBM Buffer 4 Print Out Settings 5 Print Out Character Sets L

Seite 6

2. If the permanent memory area is unreadable, the permanent memory area will be reset, the factory defaults read and an error message will be printe

Seite 7 - 2 Installation & Test

5 Special FSL Functions This section covers the special FSL features for the Printserver. The FSL functions are covered in groups according to their

Seite 8 - 3 Operation

On your printer front panel it is possible to change paper size and to set default LPI, default CPI and default print quality. These values are transf

Seite 9 - 3.2 Printer Operation

When you have specified settings for these functions, you must save them in the permanent memory with ESC X1 command, turn printer power off for appro

Seite 10 - 4.2 The Escape Character

Appendix A. FSL Functions This appendix describes all supported FSL functions with data, description, use, related functions, notes and examples. No

Seite 11

FSL Functions Supported by Coax IIF-4 No. Function 1 Buffer Size 2 LPI 3 CPI 4 Line Spacing 5 Form Length 6 Maximum Print Position 7 Case 8 Se

Seite 12 - 4.6 Testing via the Line

Table of contents 1 Introduction ...3 1.1 Printserve

Seite 13 - 4.7.2 Actions at Power-Up

FSL Function Lookup Reference FUNCTION 1: BUFFER SIZE This function is used for changing default buffer size. SYNTAX: %Y1,<n1>% OPTION

Seite 14

will set the printer to 8 LPI default. FUNCTION 3: CPI This function is used for selecting default CPI. SYNTAX: %Y3,<n1>% OPTION

Seite 15 - 5 Special FSL Functions

EXAMPLE: %Y4,2% will set the printer to double space default. FUNCTION 5: FORM LENGTH This function is used for selecting the Form Length.

Seite 16

000 Set MPP to 256 (SCS command ignored) LU1 001 to 220 Set MPP in number of characters LU3 001 to 255 Set MPP in number of char

Seite 17 - 5.3 Form Feed (FF Handling)

37 United States 256 International 273 Austria/Germany 274 Belgium 275 Brazil 276 Canada/France 277 Denmark/Norway 278

Seite 18 - Appendix A. FSL Functions

It may be necessary to re-define the escape character, otherwise it may cause problems as the escape character is defined in LU3. EXAMPLE: %Y8,30%

Seite 19

4. Function 11 = 4 (Automatic Cut--Sheet Feeder, Tray 3) will select Envelope feeder in Proprinter mode (i.e. function Y22 set to 1 or 9). Function

Seite 20

FUNCTION 23: GRAPHICS PRINTOUT This function is used for selecting horizontal compensation in graphics. SYNTAX: %Y23,<n1>% OPTION DESC

Seite 21

1. At power up the value for Form Feed after Local Copy is loaded from the front panel setup of the printer. Function X1 has no effect. 2. 3. Opera

Seite 22

4 Null line suppression in both formatted and unformatted operator initiated local copy and non- SCS print. 5 Null line

Seite 23

1 Introduction The TallyCom III Twinax/Coax/Ethernet IIF-4 Printserver (herein referred to as the Printserver) is an internal high performance interf

Seite 24

FUNCTION 28: CR AT MPP + 1 This function implements an IBM RPQ and will have effect as soon as it is received. . SYNTAX: %Y28,<n1>% OPTION

Seite 25

*0 2nd Print Position (PP) on 1st line on next form 1 1st PP of 1st line on next form RELATED: Y32, FF Valid NOTES: 1. This f

Seite 26

1. This function corresponds to the following IBM RPQ options: 4214: OPT 19=1 3268: SC9506 3287: SC3739 2. Available only in non-SCS operation.

Seite 27

This function gives you control over the use of FF codes to maintain form boundaries. SYNTAX: %Y35,<n1>% OPTION DESCRIPTION n1

Seite 28

The SCS VCS command is supported. Characters below 40 HEX not matching the valid SCS code table below are passed directly to the printer, i.e.

Seite 29

SA Set Attribute 28 EXAMPLE: %Y37,0% sets IBM 3287/4214 emulation. FUNCTION 38: IBM COMMUNICATION FEATURE This function is used to enable que

Seite 30

will suppress empty forms FUNCTION 41: Generation of NL at EM This function is used to select whether the interface should generate a New Line (N

Seite 31

FUNCTION 47: ESC MODE SELECTION This function is used for the selecting of standard escape mode and special transparency. SYNTAX: %Y47,<n1>

Seite 32

NOTES: 1. The settings must be saved using the commands "% X1" in order to make the escape character permanent. 2. The permanent escape

Seite 33

3. The printer is only considered idle after n1 has expired. 4. Share timer defined by Y100 will start after Y50 defined time elapse. 5. Chang

Seite 34

• Ethernet Set-Up The Ethernet 10/100BaseT interface is used for several purposes: 1) to setup/configure the interface; 2) to monitor the interface

Seite 35

RELATED: Y61, Setup for User-Defined Strings NOTES: 1. The user strings will have to be defined in function Y61 before they can be sent. 2. Th

Seite 36

SYNTAX: %Y61, n,<string>% OPTION DESCRIPTION n User string ID number (0-7) string User string contents in HEX and/or charac

Seite 37

SYNTAX: %Y75,<n1>[,n2],<data>[:n1,n2,<data>]% OPTION DESCRIPTION n1 HEX value The position of the value to be translated

Seite 38

%W2,2222222% Print "2222222" according to the specification above. <NL> 8 <NLs> (= height) to avoid

Seite 39

X1 Save the temporarily defined settings in the permanent memory (FLASH) X3 Restore the settings to factory default settings and reset printer

Seite 40

Appendix B. Bar Code Printing Note: Please note that bar code printing depends on the printer in which the Printserver is installed. For further in

Seite 41

6. UPC Five-digit Supplemental (Paperbacks) 7. EAN-8 (includes JAN-short) 8. EAN-13 (includes JAN-standard) 9. Industrial 2-of-5 10. Matrix 2-of

Seite 42

Industrial 2 of 5 is a numeric bar code type with automatic checking, numerical and variable length. Start, stop and center codes are generated auto

Seite 43

Appendix C. Error Messages C.1 Recoverable errors Recovery procedure from these errors is as follows: Correct the error from the host system acco

Seite 44

8005 Wrong interrupt from COAX IF. 8006 No test response from COAX IF. 8007 Invalid test response from COAX IF. 8010 Nothing recei

Seite 45

1.4 Items Supplied with Printserver Before you begin installing the Printserver, make sure that you have all the items shown below. • Printserver •

Seite 46

Appendix D. Test Printout Pages D.1 Test 2: Online Hex Dump (Coax) Note: The PCIA (printer controlled information area) is the first 5 rows in the

Seite 47

Case # 7 1 LU1 Language # 8 0 Quality # 9 1 Paper Path # 11 1 Printer driver # 22 1 FF before Local Copy # 25 0 F

Seite 48 - Appendix C. Error Messages

TCP/IP Settings TCP/IP : Enabled FTP : Enabled Host Name : IP Lookup Method

Seite 49 - C.3 FLASH PROM Errors

Access Authorizations (1) Community Name : public Access Rights : Read and Write (2) Community Name : internal

Seite 50 - Printserver – FSL Settings

Status : Registered Telnet Print : TN3270E Device name : Host IP address : 0.0.0.0

Seite 51

D.3 Test 5: Character Sets D.3.1 LU1 (Coax) 55

Seite 52

D.3.2 LU3 (Coax) 56

Seite 53

Appendix E. Abbreviations Abbreviation Full name Explanation AFP Advanced Function Presentation IBM concept for print data formatting that defines

Seite 54

Abbreviation Full name Explanation IPDS Intelligent Printer Data Stream IPDS is generated and sent by e.g. PSF and translated by the PrintServer

Seite 55 - D.3 Test 5: Character Sets

Abbreviation Full name Explanation PPD Page Printer Demon Enhanced version of LPR/LPD that supports IPDS protocol. The enhancement enables bi-dire

Seite 56 - D.3.2 LU3 (Coax)

Figure 1, Printserver installed in printer 6

Seite 57 - Appendix E. Abbreviations

60 Abbreviation Full name Explanation TCP/IP Transmission Control Program/Internet Protocol Suite of programs for network communication. TCP/IP can

Seite 58

2 Installation & Test 2.1 Installation 1. Power off printer. Install the Printserver following the Installation Guide instructions. 2. Connect

Seite 59

3 Operation The Printserver is designed to be operated via the line (host connection). The standard control panel is fully operational, but some limi

Seite 60

CU Indicator The CU indicator has 3 states which signal the following: State Indication OFF No contact to the control unit (no power) or the conta