Dascom 7010 Programmers Manual ZPL Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10
B = bottom-up 270 degrees, read from bottom up
Initial Value at Power-up: N
Comments:
If the ^FW command is entered with the r parameter missing, the command is ignored.
^FW only affects the orientation in commands where the rotation parameter has not been specifically
set. If an command has a specific rotation parameter, that is the once that is used.
^PO
Print Orientation
Description:
The ^PO command inverts the label format 180 degrees. In essence, the label is printed upside-down.
If the original label contains commands such as ^LL,^LS the inverted label output will be effected
differently.
Format: ^POa
Parameters:
a = invert label 180 degrees
Accepted Values: N(normal) or I(invert)
Default Value: N
Comments:
If multiple ^PO commands are issued in the same label format, only the last command send to the
printer is used.
Once you issue a ^PO command, the setting is retained until another ^PO command is received or
the printer is powered down.
^FO
Field Origin
Description:
The ^FO command sets a field origin, relative to the label home(^LH) position. ^FO sets the
upper-left corner of the field area by defining points along the x-axis and y-axis independent of the
rotation.
Format: ^FOx,y
Parameters:
x = x-axis location(in dots)
Seitenansicht 9